Zotop


Zotup L 3/30 120 1 Pole SPD
High-quality surge protection device for single-phase applications.
- Rated Voltage: 230V
- Max Discharge Current: 30kA
- Poles: 1P
Technical Details
- Remote reporting contact: Potential-free changeover contact
- Response time: 25 ns
- Behavior in case of end of life: OCM
- Modes of protection: 1
- Rated load current: 125A
- Charge: 12.5 As
- Dimension (width): 35 mm
- Approximate weight: 170 g
- Nominal voltage: 230 V ac
- Product Brand: Zotup
Features and Benefits
- Classification for impulse testing: Test Class II according to IEC 61643-11 Ed.1 and Type 2 according to EN 61643-11
- Withstands a short-circuit current of: 50 kA eff. with maximum protective fuse
- NFC No Follow Current® SPD: Prevents circulation of subsequent network current after intervention
- Model Name: L 3/30 120


Zotup L 25/100 230 FF 2 Pole SPD
Compact 2P SPD suitable for residential and commercial protection.
- Rated Voltage: 230V
- Max Discharge Current: 100kA
- Poles: 2P
Technical Details
- Remote reporting contact: Potential-free changeover contact
- Response time: 25 ns
- Behavior in case of end of life: OCM
- Modes of protection: 1
- Rated load current: 125A
- Charge: 12.5 As
- Dimension (width): 35 mm
- Approximate weight: 395 g
- Nominal voltage: 230 V ac
- Product Brand: Zotup
Features and Benefits
- Model Number: L 25/100 230 Ff
- Impulse test classification: Test class I and II according to IEC 61643-11 Ed. 1 (2011-03) and Type 1 and 2 according to EN 61643-11 (2012-10);
- L 25/100 230 t ff is a voltage limiting SPD for the protection of low voltage installations and equipment against direct and indirect lightning effects;
- Backup protection: Not required with an upstream CB ≤ 160 A or up to an Isccr ≤ 5 kA rms;
- Impulse current: Is divided into two independent branch circuits, each branch providing its own disconnector and Status Indicator;
- Three colour Status Indicator: With progressive indication of remaining performance.
- Poles: 2 Poles


Zotup L 25/100 230 FF 3 Pole SPD
Reliable three-phase SPD for industrial protection requirements.
- Rated Voltage: 230V
- Max Discharge Current: 150kA
- Poles: 3P
Technical Details
- Remote reporting contact: Potential-free changeover contact
- Response time: 25 ns
- Behavior in case of end of life: OCM
- Modes of protection: 3
- Rated load current: 125A
- Charge: 12.5 As
- Dimension (width): 53 mm
- Approximate weight: 550 g
- Nominal voltage: 230 V ac
- Product Brand: Zotup
- Made in: Italy
Features and Benefits
- L 25/100 230 FF Model Number
- Impulse test classification: Test class I and II according to IEC 61643-11 Ed. 1 (2011-03) and Type 1 and 2 according to EN 61643-11 (2012-10)
- Backup protection: Not required with an upstream CB ≤ 160 A or up to an Isccr ≤ 5 kA rms
- Three colour Status Indicator: With progressive indication of remaining performance
- Poles: 3 Poles


Zotup L 2/10 230 FF 4 Pole SPD
Advanced 3P+N SPD for high-demand industrial applications.
- Rated Voltage: 415V
- Max Discharge Current: 200kA
- Poles: 3P+N
Technical Details
- Nominal voltage: 230 V ac
- Modes of protection: 3
- Product Brand: Zotup
- Charge: 12.5 As
- Dimension (width): 70 mm
- Remote reporting contact: Potential-free changeover contact
- Approximate weight: 780 g
- Rated load current: 125 A
- Response time: 25 ns
- Behavior in case of end of life: OCM
Features and Benefits
- Model Number: L 2/10 230 FF
- Impulse test classification: Test class II according to IEC 61643-11 Ed. 1 (2011-03) and Type 2 according to EN 61643-11 (2012-10)
- L 2/10 230 ff 4: Voltage limiting SPD for the protection of low voltage installations and equipment against indirect lightning effects
- Backup protection: Not required with an upstream CB ≤ 160 A or up to an Isccr ≤ 5 kA rms
- Short circuit current withstand: 50 kA rms with max. back-up fuse
- NFC No Follow Current® technology: No follow currents drawn from the power supply system after operation
- Three colour Status Indicator: Progressive indication of remaining performance
- Height: 90 mm
- Poles: 4 Poles


About ZOTUP
Leading the Way in Surge Protection Technology
ZOTUP is a forward-thinking company dedicated to providing state-of-the-art surge protection solutions for low, medium, and high-voltage electrical systems. With over 4.5 years of dedicated research and development, our team has created industry-leading products designed to ensure the safety, reliability, and longevity of your electrical infrastructure. Backed by more than 360 laboratory tests and 5 international patents, ZOTUP products set a new benchmark in surge protection technology.
We are committed to offering our customers cutting-edge, high-performance solutions that deliver unmatched safety and dependability.
Our Mission
At ZOTUP, our mission is clear: To protect critical electrical systems and infrastructure from the devastating effects of surges and overvoltages. We aim to set the standard in surge protection technology by providing reliable, innovative, and cost-effective solutions that offer superior protection for both industrial and commercial applications.
What Makes ZOTUP Different?
ZOTUP stands out in the field of surge protection due to our commitment to continuous improvement and technological innovation. Here’s why ZOTUP is the trusted choice for surge protection:
- Patented Technology: We hold 5 international patents for unique technologies that ensure top-tier performance and reliability.
- Extensive Testing: With over 360 rigorous lab tests, ZOTUP products are built to withstand the toughest electrical environments and exceed industry standards.
- Durability: Our products are designed to provide long-lasting protection, even in harsh environmental conditions like extreme temperatures and high levels of pollution.
- Ease of Use: Our surge protectors are designed for easy installation and minimal maintenance, making them the ideal choice for time-sensitive projects.
Innovative Features of ZOTUP Surge Protectors
ZOTUP surge protection devices feature several groundbreaking innovations that ensure both superior performance and ease of use:
- Internal Disconnector (Fuse Function): ZOTUP’s patented Fuse Function ensures an open circuit failure in the event of the end-of-life of the surge protector, eliminating the need for additional back-up fuses. This design reduces space, lowers voltage drops, and ensures a safer and more reliable installation.
- Progressive Performance Indicator: The visual indicator allows you to monitor the degradation of the surge protector, ensuring preventive maintenance and avoiding costly downtimes.
- Pollution Degree 3 Certification: ZOTUP products are engineered to withstand severe environmental conditions, including conductive pollution, humidity, salt, and dust, ensuring operational reliability even in challenging environments.
- High Withstanding Capacity Against Temporary Surges: ZOTUP surge protectors are designed to safely handle both transient and temporary overvoltages (TOV), providing ongoing protection in environments with frequent voltage spikes.
Why Choose ZOTUP for Your Surge Protection Needs?
- Reliable Protection: Our products are rigorously tested to ensure they meet the highest safety and performance standards.
- Innovation & Patents: With 5 international patents and over 360 lab tests, we’re constantly innovating to stay ahead of industry trends and provide the best protection solutions.
- Global Reach: ZOTUP is trusted by electrical engineers, facilities managers, and contractors worldwide for its top-quality surge protection devices.
- Customer-Centric Approach: We prioritize customer satisfaction by offering dedicated support, easy-to-understand documentation, and solutions tailored to specific needs.
Commitment to Sustainability
At ZOTUP, sustainability is a core value. We are committed to designing and manufacturing products that not only provide exceptional protection but also adhere to environmentally responsible practices. Our surge protection devices are made using eco-friendly materials and processes, ensuring that we are contributing to a greener, safer future.
Contact ZOTUP
For more information about our products, solutions, or if you need assistance with a specific project, please feel free to Contact Us. Our team of experts is ready to provide the guidance and support you need.
Discover Products
ZOTUPLIMITER
L - ZOTUPLIMITER
SPDs with varistor and NFC No Follow Current® technology offer a tripping time of ≤ 25 ns, excellent protection and impulse current up to 25 kA/pole. Ideal for high performance stand-alone applications.
ZOTUPGAP
IA - ZOTUPGAP
SPDs with spark gap and trigger technology are intended for primary protection applications where the prospective short circuit current of the power distribution system at the installation point of the SPDs is lower than or equal to Ifi.
ZOTUPGAPNPE
I - ZOTUPGAPNPE
The typical application for this device is in the N-PE mode of protection in TT distribution systems.
ZOTUPCOMB
IL - ZOTUPCOMB
Combined SPDs make use of GDT and varistor elements, with voltage switching and with voltage limiting function.
ZOTUPBOX
PB - ZOTUPBOX
Protection boxes with an IP65
ZOTUPACCESSORIES
CP - ZOTUPACCESSORIES
CPs are fork-type busbars with 2 up to 8 connection points.
ZOTUPFILTER
ILF - ZOTUPFILTER
Combined SPDs with additional filter are used where high continuity of service is required like data centers, DCS (distributed control systems), etc..
ZOTUPLIMITERDC
L - ZOTUPLIMITERDC
SPDs with varistor and NFC No Follow Current® technology offer a tripping time of ≤ 25 ns, excellent protection and impulse current up to 25 kA/pole. Ideal for high performance stand-alone applications.
ZOTUPLIMITERPV
L - ZOTUPLIMITERPV
SPDs with varistor and NFC No Follow Current® technology offer a tripping time of ≤ 25 ns, excellent protection and impulse current up to 25 kA/pole. Ideal for high performance stand-alone applications.
ZOTUPLED
LLP - ZOTUPLED
A ready to install assembly of a voltage limiting and a voltage switching SPD providing two modes of protection.
ZOTUPSIGNAL
S - ZOTUPSIGNAL
These SPDs are connected in series with low resistivity electronic equipments, like analog interfaces and data networks.
ZOTUPCOAX
C - ZOTUPCOAX
SPDs for protecting TV switchboards, satellite antenna or wideband transmission equipment and remote systems.
ZOTUPDATA
S - ZOTUPDATA
SPDs are installed on lines in series with the equipment to be protected.
ZOTUPHV
HV - ZOTUPHV
Surge Arresters for high voltage systems (HV) with typical applications: protection of transformers, switchgears and transmission lines in HV systems.
Eaton
Miniature Circuit Breakers - MCB

Range: PLSM/PLHT/PLS6 DC
Contact position Indicator: Red / Green
Rated Current: 0.5 A To 63A To 125 A
Rated Voltage: AC 230/400V DC 48V/60V/250V
Full Range Of Accessories: Shunt UV, auxiliary Switch, Trip Contact, Remote Operation
Connection as per polarity marking on the product
3 Position Mounting Clip: Easy & Quick Maintenance
Allows installation & removal of MCB / other modular devices without removing the busbar and other devices.

Insulated Sliding Shutter: Safe and Secure Termination
- Acts as guide for quick and secure termination
- Makes it impossible for wire to miss the terminal while wiring
- Insulated shutter prevents accidental contact - enhanced safety and system reliability

Contact Position Indicator
- Safe to operate, always Enables visual indication of true position of main contacts
- Ensures high degree of safety during fault conditions: Welded Main Contact / Dolly Free
- True Contact Indication

Bi Connect Terminals: Ease of Wiring
- Allows secure termination of busbars and cables simultaneously
- Looping possible without danger of loose wiring

Remote Operation and Automatic Resetting
- Remote operation
- Automatic restart in the event of undesired tripping

Unique Colour for Each Rating: Appealing Aesthetics and Easy Identification
- Colour knobs provided for better aesthetics & designer look when mounted inside acrylic door distribution board.
- The rating of MCB installed is easily identifiable by distinctive dolly colours.

Miniature Circuit Breakers - Type PLSM
- Rated current: 0.5 A to 63 A
- Rated voltage AC: 230/415V, DC: 48V (per pole)
- Rated breaking capacity: 10kA acc. to IEC/EN 60898
- Tripping Characteristics B, C, D
- Low let-through energy
- Bi connect optionally on load or line
- Endurance: 20,000 operations
- Full range of accessories: shunt, UV, auxiliary

Miniature Circuit Breakers - Type PLHT
- Rated current up to 125A
- Rated Voltage AC: 230/415V, DC: 60V (per pole)
- Rated breaking capacity up to 25kA according to IEC/EN 60947-2
- Tripping characteristics B, C, D
- Accessories: shunt trip, auxiliary switch, anti-tamper device
- Peak withstand voltage Uimp 4kV
- Endurance: 20,000 operations
- 2 Terminal Capacity: 2.5 - 50 mm²

Miniature Circuit Breakers - Type PLS6 DC
- Rated current up to 50A
- Rated voltage DC: 250V per pole, t=4 ms
- 2 poles connected in series DC: 500V
- Rated breaking capacity 10kA acc. to IEC/EN 60947-2
- Tripping Characteristics C
- Connections as per polarity marking on the product

Molded Case Circuit Breakers – MCCB

Molded Case Circuit Breakers – MCCB
- NZM1 up to 160 A
- NZM2 up to 300 A
- NZM3 up to 630 A
- AC/DC Sensitive
Residual Current Circuit Breakers – RCCB

Residual Current Circuit Breakers – RCCB
- Shape compatible with and suitable for standard busbar connection to other devices of the P-series
- Busbar positioning options (above or below)
Air Circuit Breakers – IZNX Series

- Versatile Circuit Breakers up to 4000 A - for Cost-effective, Optimized Solutions
- LCD Display with multilingual capability
- “Off” Setting available for ground fault (G) and non-delayed instantaneous trip (I)
Air Circuit Breakers - IZNX Series
Power Contactors

Power Contactor - AC & DC Operated, 3 Pole
- AC Operated Low Coil Consumption: Energy Savings
- DC Operated Electronic Actuated coil as standard from 17 A - 170 A, Optional 185 A onwards
- Coil Terminals on front as standard for quick & easy Wiring
- Type 2 Coordinated starters with PKZ MPCB’s & NZM
- MCCB
Auxiliary Contactors

Auxiliary Contactors
- Up to 4 Add-on Auxiliary contacts
- Accessories Mechanical Interlock
- DILEM, 3 POLE, DILER, 3 POLE
Contactors For Capacitors – DILK

Contactors For Capacitors – DILK
- Group compensation / 12.5 to 50 KVAR at 400V
- Voltage: up to 690V at 50-60 Hz
- Weld resistance with inrush current up to 180 x IN
- Electrical lifespan 0.15 x 106 Switches
Overload Relays

Overload Relays
- Test / Off Push Button
- Reset Push Button Manual / Auto
- Trip - Free Release
- Direct Mounting
- Overload Relay
- 1 N/O + 1 N/C
Electronic Overload Relays – ZEB

Electronic Overload Relays – ZEB
- Self supplied electronic overload relay
- Relation internal current transformer 5:1
- Ampere range 0.3A…1500A
- Up to 100A single devices
- Above 100A device + additional current transformer
Combined Residual Current Devices / Miniature Circuit Breaker Devices – RCBO (RCD+MCB)

Combined Residual Current Devices / Miniature Circuit Breaker Devices – RCBO (RCD+MCB)
- Rated breaking capacity: 6 kA & 10 kA
- Rated current: 2 A-40 A
- Operational voltage range: 196-253 V
Combined Residual Current Devices / Miniature Circuit Breaker Devices RCBO(RCD+MCB) Type PKNM

Industrial-grade pushbuttons and selectors by Eaton built for harsh environments.
- Specifications:
- Rated Breaking Capacity: 6 KA & 10 KA
- Rated Current: 2A - 40A
- Operational Voltage Range: 196-253 V
Residual Current Devices - RCD - Electromechanical

Industrial-grade pushbuttons and selectors by Eaton built for harsh environments.
- Range:
- Rated current: 16, 25, 40, 63, 80, 100, 125 A
- Number of poles: 2P, 4P
- Sensitivity: 10, 30, 100, 300, 500 mA
- Special application specific versions:
- Lamp-proof
- Frequency converter proof
- X-Ray-proof type
Pushbuttons, Pilot Lights & Selector Switches

Pushbuttons, Pilot Lights & Selector Switches
- Standard Pushbuttons rated to five million mechanical operations
- All illuminated devices feature LED light units rated to 100,000 hours
- Field-convertible pushbuttons and selector switches (momentary/maintained)
- Most components carry an IP67/69k rating, suitable for high temperature, high-pressure wash down environments
- Laser etched button-lenses and all other front-of-panel accessories can be shared with the M22 line
Distribution Boards - DB

Specifications
- Application Standard Bs EN: 50298/IS 13032 : 91
- Incomer options for 100A Isolator or/and 40A-100A
- Busbar system available in both split and non-split variants
- Removable glands plate in Flush version
- Knock outs are provided on top/bottom
- Reliable & safe operation assured through KEMA testing & certifications
Email: torquetraders88@gmail.com
Phone: 91 8879901515

Address:
Mumbai – 400 014.